[email protected]F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204 Page 80
Sequence Description Access Notes
1,4,2,1 Snsr Damp Edit Primary variable damping (time constant) in seconds
1,4,2,2,1 PV LRV Edit Primary variable low range value
1,4,2,2,2 PV URV Edit Primary variable upper range value
1,4,2,3,1 PV LRV Edit Primary variable low range value
1,4,2,3,2 PV URV Edit Primary variable upper range value
1,4,2,4 Xfer Fnctn View Linear
1,4,2,5 AI % rnge View Analog output % range
1,4,3,1,1 AO1 View Analog output, mA
1,4,3,1,2 AO alarm typ N/A Not used
1,4,3,1,3,1 4 mA View Loop test, x analog output at 4 mA
1,4,3,1,3,2 20 mA View Loop test, x analog output at 20 mA
1,4,3,1,3,3 Other Edit Loop test, x analog output at mA value entered
1,4,3,1,3,4 End Exit loop test
1,4,3,1,4 D/A trim Edit Calibrate electronics 4mA and 20mAvalues
1,4,3,1,5 Scaled D/A trim N/A Not used
1,4,3,2,1 Poll addr Edit Poll address
1,4,3,2,2 Num req. preams View Number of required preambles
1,4,3,2,3 Burst mode N/A Not used
1,4,3,2,4 Burst option N/A Not used
1,4,4,1 Distributor N/A Not used
1,4,4,2 Model N/A Not used
1,4,4,3 Dev id View Device identication
1,4,4,4 Ta g Edit Tag
1,4,4,5 Date Edit Date
1,4,4,6 Write Protect View Write protect
1,4,4,7 Descriptor Edit Vortex owmeter
1,4,4,8 Message Edit 32 character alphanumeric message
1,4,4,9 PV snsr s/n View Primary variable sensor serial number
1,4,4,menu Final assy # Edit Final assembly number
1,4,4,menu,1 Universal Rev View Universal revision
1,4,4,menu,2 Fld dev Rev View Field device revision
1,4,4,menu,3 Software Rev View Software revision
1,5 Review N/A Not used
2 PV View Primary variable value
3 PV AO View Analog output, mA
4,1 PV LRV Edit Primary variable lower range value
4,2 PV URV Edit Primary variable upper range value
5,1 PV LRV Edit Primary variable lower range value
5,2 PV URV Edit Primary variable upper range value