Onicon F-3200 Series Instrukcja Użytkownika Strona 27

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 26
11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-3200 Flow Meter Manual 05/14 - 0671-12 / 18325 Page 27
3.3.3 Power and Output Signal Wiring Instructions
Factory Default Output Congurations
ONICON pre-programs the analog and pulse outputs based on application specic data
provided at the time the meter is ordered. The tables on the next page show how the pulse
outputs are congured based on whether the application has bi-directional ow and if the
meter will be connected to an ONICON peripheral device such as an ONICON BTU meter
or display module.
In all applications the analog 4-20 mA output is available at:
Analog Output #1: terminals 9 (+) and 10 (-).
Analog Output #2: terminals 28 (+) and 20(-) - Optional output available only if
the meter was ordered with the redundant output option.
Application Pulse Output #1
Terminals: 16 (+) & 17 (-)
Pulse Output #2
Terminals: 18 (+) & 19 (-)
Standard Frequency Scaled Pulse
Bi-directional *Scaled Output Flow Direction
* This output will be congured for frequency if the ow meter is provided with a peripheral device.
Optional Auxiliary Pulse Outputs
Application Pulse Output #3, Terminals: 22 (+) & 21(-) Pulse Output #4, Terminals: 30(+) & 29(-)
Standard Flow Direction OFF
Bi-directional Flow Direction OFF
* This output will be congured for frequency if the ow meter is provided with a peripheral device.
Pulse Out 1
Pin 16 - Pos (+)
Pin 17 - Neg (-)
Pulse Out 2
Pin 18 - Pos (+)
Pin 19 - Neg (-)
4-20 mA Output 1
Pin 9 - Pos (+)
Pin 10 - Neg (-)
SIGNAL CONNECTIONS
Step 1: Remove the 4 Allen screws using a 5mm
Allen wrench.
Step 2: Remove the cover exposing the
connection terminals.
Step 3: Make SIGNAL connections as shown
Pull straight out on connectors to remove them.
Pulse Output 1 / 2 / 3 / 4
Opto-coupled open collector pulse outputs
Maximum voltage: 40VDC
Maximum current: 100mA
Maximum saturation voltage
collector/emitter @ 100mA: 3 VDC
Maximum Frequency: 1,250 Hz
connection terminals
.
AUX SIGNAL CONNECTIONS
4 - 20 mA Output 2
Pin 28 - Pos (+)
Pin 20 - Neg (-)
Pulse Out 3
Pin 22 - Pos (+)
Pin 21 - Neg (-)
Pulse Out 4
Pin 30 - Pos (+)
Pin 29 - Neg (-)
16 (out1)
18 (out2)
22 (out3)
30 (out4)
17 (out1)
19 (out2)
21 (out3)
29 (out4)
!
CAUTION
The transmitter earth connection at the input voltage terminals and the sensor body earth terminals
must both be connected to earth to ensure proper operation.